365 – AL Stop MV-Wiring Ground
ZKP-Number: 1.8004.561
Cause Corrective action
Injector cabling fault. If bit
“1.1020.021” (Power Stage
Failure: stop engine) is set,
engine will be shut down as
additional measure. 1. Short
circuit of positive connection of
one or more injectors to ground
2. Short circuit of negative
connection of one or more
injectors to ground .
1. Check cabling.
2. Attempt to restart engine.
371 – AL Wiring TO 1
ZKP-Number: 1.8004.634
Cause Corrective action
Short circuit or wire break on
transistor output 1 (TO 1).
1. Check turbocharger valve/cabling, repair as necessary.
2. Replace ECU.
372 – AL Wiring TO 2
ZKP-Number: 1.8004.635
Cause Corrective action
Short circuit or wire break on
transistor output 2 (TO 2).
1. Check recirculation valve/cabling, repair as necessary.
2. Replace ECU.
373 – AL Wiring TO 3
ZKP-Number: 1.8004.636
Cause Corrective action
Short circuit or wire break on
transistor output 3 (TO 3).
u -
374 – AL Wiring TO 4
ZKP-Number: 1.8004.637
Cause Corrective action
Short circuit or wire break on
transistor output 4 (TO 4).
u -