Operating instructions

308 – AL Timing Cylinder A8
ZKP-Number: 1.8004.507
Cause Corrective action
Time-of-flight measuring fault of
injector: time-of flight measured
value extremely low or extremely
high.
u Replace injector concerned if the fault message appears
frequently (→ Page 119).
309 – AL Timing Cylinder A9
ZKP-Number: 1.8004.508
Cause Corrective action
Time-of-flight measuring fault of
injector: time-of flight measured
value extremely low or extremely
high.
u Replace injector concerned if the fault message appears
frequently (→ Page 119).
310 – AL Timing Cylinder A10
ZKP-Number: 1.8004.509
Cause Corrective action
Time-of-flight measuring fault of
injector: time-of flight measured
value extremely low or extremely
high.
u Replace injector concerned if the fault message appears
frequently (→ Page 119).
311 – AL Timing Cylinder B1
ZKP-Number: 1.8004.510
Cause Corrective action
Time-of-flight measuring fault of
injector: time-of flight measured
value extremely low or extremely
high.
u Replace injector concerned if the fault message appears
frequently (→ Page 119).
312 – AL Timing Cylinder B2
ZKP-Number: 1.8004.511
Cause Corrective action
Time-of-flight measuring fault of
injector: time-of flight measured
value extremely low or extremely
high.
u Replace injector concerned if the fault message appears
frequently (→ Page 119).
MS150093/01E 2012-06 | Troubleshooting | 75
TIM-ID: 0000008506 - 001