Operating instructions
180 – AL CAN1 Node Lost
ZKP-Number: 2.0500.680
Cause Corrective action
Connection to one node on CAN
bus 1 failed.
u Contact Service.
181 – AL CAN2 Node Lost
ZKP-Number: 2.0500.681
Cause Corrective action
Connection to one node on CAN
bus 2 failed.
u Contact Service.
182 – AL CAN Wrong Parameters
ZKP-Number: 2.0500.682
Cause Corrective action
Incorrect parameter values
entered in data record.
u Contact Service.
183 – AL CAN No PU-Data
ZKP-Number: 2.0500.683
Cause Corrective action
ACAN mode has been selected
in which communication with the
PU data module is initialized.
However, the required PU data
module is not available or not
valid.
u Contact Service.
184 – AL CAN PU-Data Flash Error
ZKP-Number: 2.0500.684
Cause Corrective action
A programming error occurred
when attempting to copy a
received PU data module into
the Flash module.
u Contact Service.
186 – AL CAN1 Bus Off
ZKP-Number: 2.0500.686
Cause Corrective action
CAN controller 1 is in “Bus-Off”
status.
1. Inspect CAN bus for short circuit and rectify short circuit as
necessary.
2. Check shielding, improve as necessary.
3. Contact Service.
66 | Troubleshooting | MS150093/01E 2012-06