User Manual
252 Servovalve Installation
Series 252 Servovalve Product Information Installation
27
8. Apply low hydraulic pressure to the servovalve so that the hydraulic fluid
gradually fills the filter cavity.
9. Apply high hydraulic pressure and check for leaks at the servovalve
hydraulic connections and at the base of the servovalve.