User Manual

Mounting a Swivel
Series 249G2 Swivels Installation
21
Installation
This section describes how to install the Series 249 Swivels to the foundation.
For information is attaching the swivels to actuator rods, refer to the appropriate
actuator product manual.
Contents Mounting a Swivel 21
Mounting for Angularly Applied Loads 22
Rigid support for
swivel mounts
The swivel base assembly is not designed to rigidly support an actuator for
vertical operation. In general, actuators that require rigid support are equipped
with a pedestal base accessory. Should it become necessary to rigidly support an
actuator with a swivel base assembly, contact MTS Systems Corporation for rigid
support recommendations.
Mounting a Swivel
All models of the Series 249 Swivels can be mounted with four socket head bolts.
The mounting bolt size is determined by the model number. See the following
table for the recommended mounting bolt size, torque, grade, and mounting bore
thickness.
Mounting Bolt Size, Torque & Grade Requirements
Model Recommended Mounting
Bolt Size
Mounting Bolt
Torque
Recommended
Bolt Grade
Mounting Bore
Thickness
SI Metric U.S.
Customary
N•m lbf-ft IS SAE mm in
249xx.M25 M10 x 1.50 3/8 in-16 53 34 12.9 8 24.6 0.97
249xx.M70 M16 x 2.00 5/8 in-11 230 160 12.9 8 38.1 1.50
249xx.M160 M16 x 2.00 5/8 in-11 230 160 12.9 8 57.2 2.25
249xx.M340 M24 x 3.00 1 in-8 780 680 12.9 8 127 5.00
249xx.M500 M30 x 3.50 1-1/4 in-7 1600 1360 12.9 8 110 4.31
249xx.M730 M30 x 3.50 1-1/4 in-7 1600 1360 12.9 8 230 9.06
249xx.M1000 M42 x 4.50 1-1/2 in-6 3200 2400 12.9 8 312 12.30
249xx.M1550 M48 x 5.00 1-3/4 in-5 5000 3700 12.9 8 445 17.50
Mounting