Instruction Manual
Comparison of Trend Calculations to Other MTS
Applications
MPE and MultiPurpose TestWare (MPT)
Terminology Comparison
MPE and MPT Terminology Comparison
MPT TermMPE Term
Smart Limits % Based on Data ValueStatistical Percentage
Smart Limits % Based on Full RangeFull-Scale Percentage
Eng. UnitsStatistical Limits from Table
% RangeRange Percentage from Table
To emulate the default MPT table limits
1. On the workflow, click the Trend Monitoring activity.
2. On the Property panel, in the Limit Definition panel, set Upper Limits and Lower Limits to 100%.
3. For Calculation Method, select Statistical Limits from Table or Range Percentage from Table.
MTS MP and MTS RPC
The Statistic method in MTS RPC is the same as the Statistical Percentage method in MTS MP. The
Manual method in MTS RPC is the same as the Statistical Limits from Table method in MTS MPE.
Note:
MTS RPC does not define a Min value, so the range is not clearly defined.
RPC Full Scale method (using Min=-Max)
LowerLimit = Statistic – LowerPercentage * Range / 2
UpperLimit = Statistic + UpperPercentage * Range / 2
RPC Full Scale method (using Min=0.0)
LowerLimit = Statistic – LowerPercentage * Range
UpperLimit = Statistic + UpperPercentage * Range
MTS TestSuite | 643
Appendix: Trend Monitoring