How to Clean the MPCM
Operation
Remote operation Note Perform the following steps on the MPCM Supervisor.
1. Configure each HPU according to the “Set HPU to Remote Operation for
use with the MPCM Supervisor” section.
2. If not already displayed, press the Status button to display the Status screen.
3. Verify that each Unit and System does not have any faults or alarms. If a
fault or alarm exists press the Reset button to attempt to reset the fault or
alarm. If unit does not reset consult HPU manual for further information.
4. Press the Unit button to display the Unit screen
5. Verify that the Remote Operation button is green on each HPU that is to be
run. If the button is not green on a specific HPU, revisit "Set HPU to
Remote Operation for use with the MPCM Supervisor" section to insure that
the HPU has been put into remote mode.
6. Verify that at least one pump is enabled. Enable additional pumps as
necessary.
7. Start each HPU in low pressure by pressing Run for each HPU that is to be
run.
8. Check the HPU for leaks and unusual sounds. Stop the HPU immediately if
leaks or unusual sounds are noted. Determine the cause and fix the problem
before restarting the HPU.
9. Select High Pressure for each HPU that is to be at High Pressure.
Note There are other methods for running the system. Refer to the System
and Unit screen information, or the videos supplied on the CD.
How to Clean the MPCM
Remove dust and dirt from the chassis with an appropriate cleaner for
electronics.