Service Manifold Manual

Table Of Contents
Note:
Ensure that you connect the Drain Out line hose to the HPU reservoir or the drain circuit on the
hardline before you apply hydraulic pressure.
Note:
Remove a fluid cap port plug only when a hose is ready for connection. Retain these plugs for use
during service.
DescriptionItem
PressureP
ReturnR
Pilot PressurePP
-32 Return in from servovalve1
-06 Pilot Pressure Return in from servovalve2
-32 Return out to HPU3
-32 Pressure in from HPU4
-06 Filter Drain HB2 (maintenance only)5
-32 Pressure out to actuator6
-08 Drain out7
Model 293.32 Hydraulic Service Manifold | 37