Service Manifold Model 293-12B Owner's manual
DescriptionItem
Top View7
Return Out -168
Pressure In -169
Filter Drain -06 (maintenance only)10
Drain Out -06 to HPU11
Hydrostatic Bearings Controlled Pressure -0412
Pressure -1613
Return -1614
Pilot Return -0615
Drain -0616
Note:
The filter drain is provided for maintenance of the filter. The drain port is at the same hydraulic
pressure as the HPU. Ensure that hydraulic pressure to the HSM is turned off before using this drain
port.
Series 293.1X HSM Electrical Connections
The 293.1X HSM is equipped with a control manifold that permits selection of various hydraulic pressures.
Control cable connections must be made between the high and low solenoids of the HSM and the system
controller. The following figure shows the locations of the high/low solenoids.
38 | Series 293 Hydraulic Service Manifold Product Information
Installation