FGW900 High-temperature Furnace Manual Title Additional Information Product Manual be certain.
Copyright information Trademark information Publication information 2 © 2012 MTS Systems Corporation. All rights reserved. MTS is a registered trademark and MTS Criterion and MTS Insight are trademarks of MTS Systems Corporation within the United States. These trademarks may be protected in other countries.
Contents Preface 5 Before You Begin Conventions 5 6 Documentation Conventions 6 Technical Support 7 How to Get Technical Support 7 Before You Contact MTS Service Representative If You Contact MTS by Phone After you call 7 8 9 Introduction 10 About This Manual Description 10 11 Furnace 12 Temperature controller 12 Bracket of high temperature furnace Operating condition requirements Technical parameters 12 13 13 Safety Information 14 Safety 14 Hazard Placard Placement 14 Installation
Operation of Temperature Controller 28 Routine Maintenance 34 Routine Maintenance Overview Checklist 34 Declaration of Conformity 36 4 Contents FGW900 High-temperature Furnace Product Manual
Before You Begin Preface Before You Begin Safety first! Other MTS manuals Before you use your MTS product or system, read and understand the safety information provided with your system. Improper installation, operation, or maintenance can result in hazardous conditions that can cause severe personal injury or death, or damage to your equipment and specimen. Again, read and understand the safety information provided with your system before you continue.
Conventions Conventions Documentation Conventions The following paragraphs describe some of the conventions that are used in your MTS manuals. Hazard conventions Hazard notices may be embedded in this manual. These notices contain safety information that is specific to the activity to be performed. Hazard notices immediately precede the step or procedure that may lead to an associated hazard. Read all hazard notices carefully and follow all directions and recommendations.
How to Get Technical Support Technical Support How to Get Technical Support Start with your manuals The manuals supplied by MTS provide most of the information you need to use and maintain your equipment. If your equipment includes software, look for online help and README files that contain additional product information. If you cannot find answers to your technical questions from these sources, you can use the Internet, e-mail, telephone, or fax to contact MTS for assistance.
If You Contact MTS by Phone Know relevant computer information Know relevant software information For a computer problem, have the following information available: • Manufacturer’s name and model number • Operating software type and service patch information • Amount of system memory • Amount of free space on the hard drive where the application resides • Current status of hard-drive fragmentation • Connection status to a corporate network For software application problems, have the following
After you call Identify system type Be prepared to troubleshoot Write down relevant information To enable the Call Center agent to connect you with the most qualified technical support specialist available, identify your system as one of the following types: • Electromechanical material test system • Hydromechanical material test system • Vehicle test system • Vehicle component test system • Aero test system Prepare to perform troubleshooting while on the phone: • Call from a telephone close
About This Manual Introduction About This Manual Purpose The FGW900 High Temperature Furnace provides a high-temperature testing environment for material tests. These tests can include tension, compressing, or bending of ceramic, metal, and compound materials. This manual provides technical information about the high-temperature furnace in terms of its parts, working environment, technical parameters, temperature controller, installation, and operation.
Description Description The FGW900 High Temperature Furnace is primarily used with the MTS Series C45 Electronic Universal Testing Machine and the MTS Series C64 StaticHydraulic Universal Testing Machine. It provides the high temperature required for tension tests while providing a long-term, stable, high-temperature testing environment. The MTS Series FGW900 High furnace let you test materials and components within a range of temperatures, from 300~ 1100°C (572 ~ 2097°F).
Furnace Furnace The high-temperature furnace opening provides quick sample and fixture installation. The furnace has ports used for connecting thermocouples and hightemperature extensometers. The cavity of the furnace uses thermal insulation material of multicrystal mullite fiber, allowing operation at maximum temperature for extended periods of time. The heating body is made of electro thermal alloy wire which provides fast temperature rise, low heat loss, and long service life.
Operating condition requirements Operating condition requirements Only use the high temperature furnace under the following conditions.
Safety Safety Information Safety Stay clear of moving equipment/avoid crush points Stay clear of mechanical linkages, connecting cables, and hoses that move because you can get pinched, crushed, tangled, or dragged along with the equipment. High forces generated by the system can pinch, cut, or crush anything in the path of the equipment and cause serious injury. Stay clear of any potential crush points. Most test systems can produce sudden, high-force motion.
Hazard Placard Placement LABEL DESCRIPTION Do not start, operate, or service machine until you read and understand the operator’s manual. Failure to do so could result in serious injury. There are no customerserviceable parts on the MTS Criterion electromechanical frames. Burn hazard. Hot surface. Do not touch. Allow to cool before servicing. Hot surface hazard. Do not touch.
Installation The FGW900 High-Temperature Furnace is usually provided for the customer as an accessory of a main machine, and MTS service staff installs the accessory following defined steps. If it was purchased as a replacement or an additional item, install it following the steps described in this section. Installation Overview The following is an overview of furnace installation tasks: 1. Mount the furnace on the load frame. 2. Connect all electrical cables and jumpers. 3. Install the extensometer.
High temperature furnace body installation High temperature furnace body installation Furnace body installation steps: 1. Unplug the furnace rotation axis from the hinge assembly of the furnace 2. Put the furnace onto the bracket 3. Align the high-temperature furnace hinge holes with the bracket mounting holes; 4. Downwards insert the rotation axis , connect the high temperature furnace with the high-temperature bracket, as shown below: Axis of Rotation Bracket 5.
High temperature furnace body installation 5.
High temperature furnace body installation 5.2 According to the following figure shows, assemble the contact block whole piece and limit switch whole piece to the furnace bottom front position. Furnace Bottom Door Switch Assembly Touch Assembly 5.3 Use 2 Metric M4X10 socket head cap screws to lock the contact assembly piece, and then move the door switch assembly piece to make the door switch closed, after that, mover forward another 0.5mm to lock the four screws in the door switch assembly piece. c.
High-Temperature Furnace Cable Connections High-Temperature Furnace Cable Connections The connection between the high-temperature furnace and the temperature controller is shown as below: FGW900 High-temperature Furnace Product Manual Installation 20
High-Temperature Furnace Cable Connections Connection steps: 1. Connect the thermocouple wire Aaccording to the label sequence of J8, J9, and J10, insert thermocouple into the upper, middle, lower jacks of the high temperature furnace side wall and tighten the fixing screws. Insert the cable that is carried by the thermocouple into the thermocouple outlet on the rear panel of the temperature controller. To Furnace Body 2.
High-Temperature Furnace Cable Connections Lock Fastener Insert Socket 4. Connect E-STOP to the frame When connecting insert one end of E-STOP cable with E-STOP IN label into ESTOP IN socket in the rear panel of the temperature controller, then put the other end into E-STOP jack J14 on the frame controller. More detailed information about E-STOP, see related contents in the MTS load frame manual. 5.
High-Temperature Furnace Cable Connections Temperature Controller Box Computer Serial Converter Communication cable for connection FGW900 High-temperature Furnace Product Manual Installation 23
High-Temperature Furnace Cable Connections Connecting the Main Power The input voltage of the MTS FGW900 high temperature Furnace is single phase 200-240 V, 50/60 Hz. Use the cable that is provide for power input, and connect to the customer electrical box and disconnect. Note Electrical disconnect Local electrical codes supercede any information found here.
Operation This section provides typical operating instructions for the high-temperature furnace along with safety requirements. For more details about the software and the Eurotherm temperature controller, see the software operation manual and the Eurotherm temperature controller manual. Contents Operation of High Temperature Furnace Operation of Temperature Controller 26 28 CAUTION Abrasion of insulation inserts produces airborne dust.
Operation of High Temperature Furnace Operation of High Temperature Furnace Before starting test,you need assemble high temperature grip, open high temperature furnace and revolve it into test space, assemble high temperature grip into furnace body and seal pull rod hole according to requirement. The high temperature furnace belongs to split flange high temperature furnace, of which opening/closing is realized via lock on external wall of case shell.
Operation of High Temperature Furnace WARNING Improper use can shorten the life of heater elements and insulation components. Do not open the high-temperature furnace while it is hot or operating. Allow sufficient time for the furnace to cool before opening the furnace. Rapid cooling reduces heating element life.
Operation of Temperature Controller Operation of Temperature Controller The temperature controlling system of high temperature furnace allows user to connect it with the computer and set software parameters. The function of the switch and interface . FUNCTION DESCRIPTION Starts the heating Disables (stops) the heating POWER: Power switch of the temperature controller. COMM.: Communication interface. Furnace connects with the computer via this interface.
Operation of Temperature Controller The interface use 9 pins connectors and three of them are used. Pin assignments are as follows: PIN SIGNAL 1 No Contact 2 COMM A(+) 3 COMM B(-) 4 Communication GND 5 No Contact 6 No Contact 7 No Contact 8 No Contact 9 No Contact E-STOP: The J1 connector should be connected to either J14 of the Frame Controller or J2 of another Accessory with an Emergency Stop board.
Operation of Temperature Controller J2 E-STOP pin assignments are as follows: PIN SIGNAL 1 ESTOPB_OUT- 2 No Contact 3 ESTOP_OUT_MONTION- 4 ESTOP_OUT_MONTION+ 5 ESTOP3B+ 6 ESTOPA_OUT- 7 ESTOP3B- 8 ESTOP3A+ 9 ESTOPB_OUT+ 10 No Contact 11 No Contact 12 No Contact 13 ESTOP3A- 14 ESTOP_OUT+ 15 No Contact J4 pin assignments are as follows: PIN SIGNAL 1 Upper heating L 2 Middle heating L 3 Lower heating L 4 GND 5 No Contact 6 No Contact High temperature furnace heatin
Operation of Temperature Controller PIN SIGNAL 3 GND 4 Upper heating N 5 Middle heating N 6 Lower heating N The thermcouples interface (THERMCOUPLE)The three thermocouples on the furnace are connected to the socket.J8, J9, J10 plug into the upper, middle and lower segment of the thermocouple. Furnace door switch: When the door is open, cut off the limit switch that's connected to the heating power on the furnace.
Operation of Temperature Controller Heating Output L Communication Interface Temperature Controller Common Functions E-STOP Heating Output N Thermocouple Interface Door Switch Interface Power Switch Power Input The Furnace uses a Eurotherm2408 as temperature controller. The following describes the operation of manual settings and some of its methods and procedures.
Operation of Temperature Controller The measured temperature Set temperature Increase and decrease key, is used to set the temperature and ginseng 2. Setting PID Control Parameters: PID control parameters are the key parameters to control the temperature. Generally, different temperatures require different PID parameters. When setting the temperature, refer to the corresponding information to enter the correct parameters.
Routine Maintenance Routine Maintenance This section provides information regarding service of the high-temperature furnace.
Routine Maintenance • When using the furnace, try not to make contact with the inner cavity of the furnace during the process of installing a test sample to avoid causing damage to the furnace cavity. • Do not open the furnace immediately after a test is completed to avoid serious injury and prevent damage to the furnace cavity. • Clean the furnace cavity in a timely manner with a soft brush once a test is completed in order to prolong the service life of the furnace.
Declaration of Conformity FGW900 High-temperature Furnace Product Manual Declaration of Conformity 36
Declaration of Conformity FGW900 High-temperature Furnace Product Manual
m MTS Systems Corporation http://www.mts.com/en/Global/index.