Owner's manual
Failure Cycle Analysis Chart
6.3.4.0 Loading Unloading Modulus Analysis Example
A Loading Unloading chart plots modulus information for each test cycle. Index markers can be defined to
show the values from load start to end.
A loading unloading modulus analysis requires several variables. To access the Variable Editor, right-click
the analysis run in Explorer and select View .
To perform an analysis of modulus loading unloading:
1. Click New Cycle Marker Chart.
2. Click New Variable, type MarkerLoadingStart, and click OK.
3. Type the following values into the table.
MarkerLoadingStart
DescriptionItem
Loading UnloadingCategory
MarkerLoadingStartIdentifier
Marker Loading StartDisplay Name
0Default Value
CountDimension
MTS TestSuite™ Fatigue Analyzer User Guide 63