Instruction manual

Page 1884 of 3156 Limited Access to Overlays
553-3001-306 Standard 10.00 January 2002
Only system administrators, logged in using PWD1 or PWD2, can access the
Audit Trail from Overlay 22.
Administrators can change the size of the Audit Trail buffer, which can be
from 50 to 1000 words (divisible by 50). When the buffer is full, new records
overwrite the oldest information in the buffer (message OVL401 is sent to the
active TTY and all maintenance TTYs). Printing the Audit Trail in
Overlay 22 clears the buffer.
Operating parameters
The LAPW feature should only be enabled on a system with a completed
Configuration record in Overlay 17 (a Meridian 1 or SL-1 machine that is
already up and running). All passwords defined within the feature must be
unique. Users and administrators cannot have more than one password
defined for any one access configuration.
Feature interactions
Set-Based Administration Enhancements
The Set-Based Administration access passwords which are added to LAPW
are subject to the same conditions as the overlay access passwords with the
following exceptions:
Set-Based Administration passwords must be numeric.
There is no maximum number of login attempts for Administrator or
Installer sets. Lockout procedures are not used.
Figure 53
Example of Audit Trail printout (Overlay 22)
DAT 01/02
LOG 08:01 #03 10 11
LOG 09:32 #04 15 10 21 57 22 11 15 21
14 15
LOG 11:21 #99 12
LOG 16:35 PWD2 15 17