Instruction manual

Italian Periodic Pulse Metering Page 1869 of 3156
Features and Services
Feature packaging
This feature is packaged under the existing 2 Mbps Digital Trunk Interface
(DTI2) package 129. Periodic Pulse Metering/Message Registration (MR)
package 101 is required for its operation.
Feature implementation
Task summary list
The following task is required:
LD 73 Configure the Italian PPM option.
LD 73 Configure the Italian PPM option.
Feature operation
No specific operating procedures are required to use this feature.
Prompt Response Description
REQ CHG Change.
TYPE DTI2 2 Mbit digital trunk.
FEAT LPTI Loop timers.
LOOP nnn Loop number.
...
ITPP (NA) YES NO Italian PPM option. If this is set, PPM pulses are only
counted when the B bit is zero.
NA = The DTI2 card is not capable of Italian PPM (the
default).
YES = Turn on Italian PPM in DTI2 card.
NO = Turn off Italian PPM in DTI2 card.