Instruction manual
Page 1867 of 3156
Features and Services
Italian Periodic Pulse Metering
Contents
The following are the topics in this section:
Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1867
Operating parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1868
Feature interactions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1868
Feature packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1869
Feature implementation . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1869
Task summary list . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1869
Feature operation . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1869
Feature description
A new vintage 2 Mbps Digital Trunk Interface (DTI2) card is introduced with
this feature. The Italian Periodic Pulse Metering (PPM) feature enables this
new DTI2 card to count PPM pulses on Italian DTI2 trunks.
In Italy, a pulse on the A bit while the B bit is zero (P0UU) is considered a
valid PPM pulse. However, a pulse on the A bit while the B bit is one (P1UU)
should not be considered a valid PPM pulse.