Intelligent Peripheral Equipment Software Support Enhancements Page 1803 of 3156
Features and Services
LD 16 – Configure the Autoguard Repeat Prevention timer for the route.
LD 97 – Configure the five XFALC timers to support downloading.
Note: For Timer Settings, the value set for the TDP timer must be less
than or equal to the setting for the switchhook flash timer. The TDPO
timer must be greater than the TDP timer. All timer values must be
entered in five milliseconds increments. Otherwise, the value is rounded
to the closest inferior multiple of five.
Prompt Response Description
REQ
TYPE RDB Route Data Block.
...
CNTL YES Responding YES to this prompt will display the TIMR
prompt below.
TIMR ARP 1-(3)-255 Autoguard Repeat Prevention timer.
For Australia, the recommended value of ARP is 200
seconds.
Prompt Response Description
REQ
FLSH
TOHV 0-(250)-1275 Off-hook validation timer, in milliseconds.
TDP (15)-1275 Minimum time for dial pulse, in milliseconds.
TID 0-(150)-1275 Interdigit timer, in milliseconds.
TDPO 15-(150)-1275 Maximum time for dial pulse, in milliseconds.
TPF 0-(200)-1275 Post-flash timer, in milliseconds. Prompted only if MPO is
equipped.