Instruction manual
Page 1758 of 3156 Instant ISM
553-3001-306 Standard 10.00 January 2002
Electronic Brand Line (EBLN/BRAND)
Unlike other ISM parameters which define the maximum configuration limits
for various resources, the BRAND ISM parameter defines which Electronic
Brand Line feature option the system is allowed to use.
The same limitation applies to the BRAND parameter as applies to other ISM
limits, that is, the BRAND parameter must be unchanged or increased if the
ISM limits are to be updated instantly without the need for a Sysload.
Once the BRAND ISM parameter has been increased, the user still has to load
overlay 17, in order to configure the actual string that is to be displayed, as
per existing operation.
Telephone displays that display brandline information (when in an idle state)
will not have the brandline updated immediately. The update will occur on a
set the next time LAMPAUDIT audits the set.
Feature packaging
This feature is included in base X11 System Software.
Feature implementation
There are no specific implementation procedures for this feature.
Feature operation
Feature operation is further broken down into three options:
1 Instant ISM parameter upgrade using a keycode diskette
2 Instant ISM parameter upgrade using HyperTerminal
3 Instant ISM parameter upgrade for Option 11C