Forced Camp-On and Priority Override Page 1573 of 3156
Features and Services
LD 15 – To select either automatic or manual forced Camp-On for a customer, respond to the
AFCO prompt with either YES (automatic) or NO (manual).
LD 16 – At the PLEV prompt, specify priority levels for trunk routes.
LD 57 – The Enhanced Override flexible feature code must be defined by responding to the EOVR
prompt with an appropriate FFC digit sequence to be assigned that function.
Prompt Response Description
...
AFCO (NO) YES (Manual) Automatic Forced Camp-On, prompted with
Priority Override/Forced Camp-On (POVR) package 186.
Prompt Response Description
...
PLEV 0-(2)-7 Priority Level, prompted with Priority Override/Forced
Camp-On (POVR) package 186.
2 = set can override sets of level 1 and 2, and can be
overridden by sets of level 2-7
Prompt Response Description
...
- EOVR xxxx Enhanced Override (manual Forced Camp-On followed by
Priority Override).