Instruction manual
Page 1456 of 3156 Extended Flexible Central Office Trunk Software Support
553-3001-306 Standard 10.00 January 2002
The following table summarizes the downloaded software configurations that
each XFCOT card supports.
Operating parameters
The flash hook implementation for the Centrex Switchhook Flash feature
does not provide flexible timing, as is provided by non-XFCOT packs. The
timing is hard-coded onto the pack at 90 milliseconds.
Table 44
Downloaded configurations for XFCOT cards
XFCOT card Hardware
I.D.
supported
Signaling supported Downloaded
SUPN
supported
Periodic Pulse
Metering (PPM)
NT5K18AA 01, 13, 14 COT (GRD, LGR, LDC) SUPN per pack
NT5K16BA 00, 01 COT (LOP, GRD) BTS per pack & unit
NT5K70AA 00 COT (LOP) BTS per unit
NT5K71AA 00 COT (LOP) BTS per unit
NT5K82AA 00 COT (LOP) BTS, LBS,
BAR
per pack & unit
NT5K90AA 00 COT (LOP) BTS, ARF per unit
NT5K90BA 00 COT (LOP) none
NT5K93AA 00 COT (LOP) BTS per pack & unit
NT5K93BA 00 COT (LOP) BTS none
NT5K99AA 00 COT (LOP) BTS per unit
NTAG03AA 00 COT (LOP) BTS per pack & unit
NTAG04AA 26, 27 COT (ALS) DID (EAM) per pack & unit