Instruction manual

Page 1000 of 3156 China – Busy Tone Detection
553-3001-306 Standard 10.00 January 2002
LD 14 – Busy Tone Detection Table and Busy Tone Supervision assignment.
Feature operation
No specific operating procedures are required to use this feature.
Prompt Response Description
REQ NEW Create or change a route.
TYPE COT Central Office trunk.
TN l s c u
c u
Trunk Terminal Number.
Terminal Number for the Option 11C.
XTRK EXUT Extended Universal Trunk.
...
SIGL LOP Loop Start signaling.
...
SUPN (NO) YES Supervision.
STYP
(PIP)
BTS
BST
PIP BTS
BST BTS
Supervision type, where:
PIP = Polarity Insensitive
BTS = Busy Tone Supervision
BST = Both way Supervision Trunk (BST) (i.e., PIP on both
incoming and outgoing calls)
PIP BTS = PIP and BTS, and
BST BTS = BST and BTS.
BTDT (0)-7 Busy Tone Detection Table number.