Page 1330 of 3156 Directory Number Expansion
553-3001-306 Standard 10.00 January 2002
ACD Load Management
ACD Load Management commands have been modified to allow longer DN-
related fields (ACD DN, position ID, route access code).
Automatic Identification of Outward Dialing
The Automatic Identification of Outward Dialing (AIOD) station identifier
and trunk identifier remains four digits long. If the total number of digits in
the AIOD prefix and internal DN exceeds four, only the leading digits of the
station DN are retained as the AIOD identifier.
Automatic Number Identification
If the DN Expansion package is equipped, the Automatic Number
Identification billing number (ANAT) can have up to seven digits. The total
number of digits for ANAT and Automatic Number Identification listed DN
(ANLD) cannot exceed seven.
Auxiliary processors
Any AUX or application processor that shares or exchanges Meridian 1
internal DN-related information with the system must be modified to handle
the longer DN format. Otherwise, only the four trailing digits will be included
in the message.
The presence of DNXP has an impact on the following types of AUX:
• Auxiliary Processor Link (APL)
• Application Module Link (AML)
• Standard Serial Data Interface (SDI) with application interface to the
Meridian 1, and
• Standard SDI without application interface to the Meridian 1.
Background Terminal Interface
When the DNXP package is equipped, any background terminal command,
response, or display containing a DN is allowed to have a DN of up to seven
digits.