Instruction manual
Page 1310 of 3156 Direct Inward System Access on Unsupervised Trunks
553-3001-306 Standard 10.00 January 2002
Operating parameters
There are no operating parameters associated with this feature.
Feature interactions
There are no feature interactions associated with this feature.
Feature packaging
Direct Inward System Access (DISA) package 22.
Feature implementation
Task summary list
The following task is required:
LD 16 – Configure the Timed Forced Disconnect Timer.
LD 16 – Configure the Timed Forced Disconnect Timer.
Note: In addition, make sure the DISA feature is configured as
described in the DISA feature description contained within this
document.
Feature operation
To dial into the system from the public network:
1 Dial the DISA number. You hear a dial tone.
2 Dial the security code, if required.
3 Dial the Authorization Code, if required.
Prompt Response Description
...
MFC (NO) YES Respond with YES to enable Multifrequency Compelled
Signaling.
- TIMR TFD (0)-3600 Timed Force Disconnect in 30-second increments.