Instruction manual
Page 1268 of 3156 Digital Trunk Interface – Commonwealth of Independent States
553-3001-306 Standard 10.00 January 2002
LD 73 – Define DTI2 data.
Prompt Response Description
REQ CHG Change.
TYPE DTI2 DTI2 Data Block.
FEAT LPTI Loop timers and some other per DTI2 loop defined
parameters.
LOOP <loop> DTI2 loop number.
CDTI2 YES CDTI2/CSDTI2 card.
P DIGIT (S) PXXX DP outpulsing will be sent on signaling bit A.
P METR (R) NO Pulse Metering.
SASU 1024 Seize Acknowledgment Supervision timer is defined in
milliseconds (rounded to the closest multiple of 128
milliseconds).
MFAO YES Multi-frame alignment option used.
SZNI NO Seize Not Idle option not used.
LCLB NO Lockout Clear Back option (send CLR-BK signal to DID in
lockout) not used.
UCFS 1101 Unequipped Channel Fault Signal – ABCD bits to be sent
on unequipped channel. The default value of 1101 is
acceptable.
MFF (AFF) CRC Alternate Frame Format or CRC4 may be chosen.
...
FRFW NO Prompted only if French Type Approval (FRTA) package
197 is equipped.
CISFW YES Prompted only if Commonwealth of Independent States –
Digital Trunk Interface (CIST) package 221 is equipped and
CDTI2 = YES.