Instruction manual

Conference Warning Tone Enhancement Page 1183 of 3156
Features and Services
LD 56 Configure Conference Warning Tone.
Prompt Response Description
REQ CHG Modify existing data.
TYPE FTC Flexible Tones and Cadences data block.
TABL 0 FTC table number 0. Only table number 0 can be used to
make changes to the Conference Warning Tone.
...
RING NO Modify the ringing feature definitions.
HCCT YES Modification of the hardware controlled cadence tone
definitions allowed.
...
- EEST NO End-to-end Signaling type.
- CFWT Conference Warning Tone.
- - XTON 0-(3)-255 The Conference Warning Tone number. A tone number
provided by the tone circuit.
- - XCAD 0-(19)-255 The Conference Warning Tone cadence number. Cadence
number must have been previously set up within LD 56 by
responding to the TYPE prompt with FCAD.