Instruction manual

Page 1182 of 3156 Conference Warning Tone Enhancement
553-3001-306 Standard 10.00 January 2002
The Conference Warning Tone can be enabled or disabled via the CWFT
prompt in overlay program. When the tone is enabled, a permanent speech
path connection is placed from the tone circuit to the conference circuit to
provide the tone to all parties connected in a conference. The tone and
cadence for the Conference Warning Tone can be programmed to be
distinctively different from the tone and cadence produced by the Intrusion
Tone given by such features as Barge-In, Break-In, or Busy Verify.
Operating parameters
This feature only applies to the Meridian 1 Option 11C.
The Conference Warning Tone will only be contained and defined within
FTC Table 0. All other FTC tables will not contain any references to the
Conference Warning Tone and this tone cannot be copied to any other FTC
table by a numbered response to the DFLT (Default to existing FTC tone
table) prompt in overlay program. Since existing code does not allow FTC
table 0 to be deleted, there is no danger of deleting the Conference Warning
Tone.
For cadence tables, table numbers above 15 should be chosen for the
Conference Warning Tone, because cadence tables numbers below 15 are
influenced by Software Controlled table numbers.
Feature Interactions
Tones and Cadences
There are no changes to the limitations to cadence numbers entry values. The
same restriction still applies.
Feature packaging
This feature is included in base X11 System Software.
Feature implementation
Task summary list
The following is a summary of the tasks in this section:
1 LD 56 Configure Conference Warning Tone.
2 LD 97 Enable Conference Warning Tone.