Page 1140 of 3156 CLASS: Visual Message Waiting Indicator
553-3001-306 Standard 10.00 January 2002
LD 13 - Configure the CLASS modem unit (up to 255 CLASS modem units may be configured
per Meridian 1 system).
Note: You may print the CMOD unit information using LD 20.
Feature maintenance and diagnostics
LD 30 and LD 32
LD 30 and LD 32 handle CLASS VMWI messaging, in the case that a CMOD
unit or a CLASS set is in the state of being disabled. Any CLASS VMWI
message that is in progress will be aborted. A check every 10 seconds, for up
to 2 1/2 hours, will be done on the CLASS set until another CMOD unit is
found or the CLASS set is enabled, before a VMWI message is actually sent
to the set to perform visual indication.
LD 77
LD 77 is used to monitor CLASS VMWI messaging.
Feature operation
No specific operating procedures are required to use this feature.
...
Prompt Response Description
REQ NEW
CHG
Add new data
Change existing data.
TYPE CMOD CLASS modem unit.
DMOD 1-127 Default Model number for this route
TN l s c u
c u
Modem unit Terminal Number for Options 51C, 61C,81C,
where l = loop, s = shelf, c = card, u = unit.
For Option 11C, where c = card, u = unit.
Note: Since the CLASS modem unit uses the octal-
density Extended CLASS Modem Card (XCMC), up to 32
units can be configured on any XCMC card.