Instruction manual
Page 1970 of 3156 Malicious Call Trace
553-3001-306 Standard 10.00 January 2002
LD 15 – Set up the recorder and alarm options.
LD 16 – Set up the alarm for external calls.
CUST 0-99 Customer number.
RTMB xxx xxx Trunk route and member number for RCD.
Prompt Response Description
REQ: CHG PRT END Change, print, or end.
TYPE: FTR Gate opener.
CUST 0-99 Customer number.
...
- ALDN xxxxxxx DN for the alarm (the DN must be on the local system).
- ALRM (NO) YES The ALRM prompt appears only if ALDN is defined.
ALRM has to be set to YES if the alarm is to be rung for any
call (external or internal) when MCT is activated.
- TIME 0-(15) Time is prompted only if ALRM is set to YES. Time for the
alarm is set in one-minute increments from 1 to 15.
- INT (NO) YES INT is prompted only if ALRM is set to YES. In addition, INT
must be YES if the alarm is to be rung when MCT is
activated against internal calls.
- RECD (NO) YES If the user wants the recorder, set RECD to YES. This
prompt does not appear when a new customer is being
defined.
- - MCRT xxxx The user has to use the recorder route number defined in
LD 16. It will only be prompted if the RECD is set to YES.
Prompt Response Description
REQ NEW
CHG
Add new data.
Change existing data.