User's Manual
13
2.7.4 The Soldering Jumpers
JP1 to JP8 Adjustment only for devices without resolver.
JP9 Closed when operating the device as speed controller, open for current
control.
JP10 As JP9
JP11 Open when operating the device as speed controller, closed for current
control
JP12 Only for adjustment by factory
JP13 Only for adjustment by factory
2.7.5 The Internal Potentiometers
P6 Only for adjustment by factory
P7 Only for adjustment by factory
P8 For special requirements to clock frequency of the power amplifier a
potentiometer can be used here (normally no components inserted)
P9 Only for adjustment by factory
P10 Only for adjustment by factory
2.7.6 The DIP switches
S1 Adjustment to pole number of the motor
1 2 Poles Comment
on on 8
off on 6 Delivery condition
on off 4
off off 2
S2 Adjustment of the number of pulses per rotation from incremental encoder
simulation
1 2 Pulse
number
Comment
off off 128
off on 256
on off 512 Delivery condition
on on 1024