Installation Sheet
10
INSTALLATION INSTRUCTIONS FOR CLAWFOOT TUBS
All MTI clawfoot tubs require an exposed drain kit. MTI recommends the use of our drain kit to ensure a
perfect t. This tub is designed to have the drain (back) side of the tub face the wall. Set tub in nal location,
and use a 6" level on top of the tub, to ensure tub is perfectly level from side to side, and front to back.
Adjust the leveling feet if necessary. The tub will not drain properly if not perfectly level.
Install drain kit and water test for leaks. Proper drain installation is the responsibility of the installer. MTI does
not warrant leaks from drain kits.
Note: Access from below tub is recommended for installation. If there is no access from below, the
installation may be more difcult and clearance will be necessary to connect the T-piece assembly to the
p-trap from above.
MTI recommends using clear 100% silicone sealant, DO NOT use plumber’s putty.
1. Place the tub in the exact position of final
installation. The bathtub cannot be repositioned
once it is plumbed and installed. The tub is
designed to sit on top of the finished floor.
2. Ensure location is structurally sound, flat and level.
3. Temporarily 'dry fit' the drain kit and trim the pipes
to proper length if necessary. Note the distance
from the outside edge of the pedestal to the center
of the overflow pipe. This measurement will be
used to determine the location of the hole in the
floor for the connection to the p-trap.
4. Remove the drain kit from the tub and set tub in
desired location. Check to ensure tub is level and
adjust leveling feet if necessary.
5. Using the distance noted in step #3, drill 2 1/4"
diameter hole in floor for overflow pipe. Note: this hole
may need to be enlarged to facilitate tightening the
slip joint.
6. Re-assemble drain kit on tub using clear silicone
under drain strainer. Remove excess silicone
immediately. Tighten waste flange assembly and
ferrule until seated plus 1/4 turn.
7. Connect the 'P-trap' to the drain kit.
Tighten all slip joint connections, thread stopper assembly into waste ange and attach overow cover.
Fill tub to overflow and allow water to stand for 30 minutes. Check carefully for any leaks. NOTE: The
overflow is a plumbing device designed to prevent water from reaching a certain level in your tub. DO NOT,
under any circumstances, tape off or block the overflow in any way.
MTI does not warrant leaks associated with improper drain installation and will not be responsible for any
costs involved with removing or reinstalling the tub. Failure to properly check oor for level will result in
improper draining of the bath. If you need assistance, please call our technical service department at 800-
783-8827.
Cover
Clamp Plate
Ferrule
Overflow
Bell Flange
Compression Nut*
Drain Stopper Assembly
Waste Flange Assembly
Drain Shoe
Compression Ring*
Compression Gasket*
*Note: compression
parts are repeated
Tailpiece
Hex Bolt Stem
Assembly
T-piece assembly
CLAWFOOT TUB DRAIN KIT -
PARTS BREAKOUT