Specifications
www.magna-power.com 5
LXI TCP/IP Ethernet Interace Option (+LXI)
LXI is an instrumentation platform based on industry stan-
dard Ethernet technology designed to provide modularity, fl ex-
ibility and performance to small- and medium-sized systems.
Certifi ed to the LXI Standard (Class C), Magna-Power Elec-
tronics +LXI option includes an embedded web-server, allow-
ing web browser power supply control and monitoring from
virtually anywhere and a universal IVI driver.
Remote Interface Software
The Remote Interface Software ships with all power supplies.
The software provides the user with an easy and intuitive
method to operate a Magna-Power Electronics power supply
with computer control. The Remote Interface Software has
six windows: Virtual Control Panel, Command Panel, Register
Panel, Calibration Panel, Firmware Panel, and Modulation
Panel.
Key Product Line Features:
Magna-Power Electronics has designed its products from
the ground up to provide synergy across the entire prod-
uct line. The following are some the company’s program-
mable DC power supplies key features:
• Industry leading power density
Rack-mount space is always at a premium. Magna-
Power Electronics power supplies are continuously
refi ned with new technology and devices to drive
down size and increase power density.
• High accuracy programming
±0.075% full scale programming accuracy on all
models and programming interfaces.
• High power factor: > 0.92 on all 3Φ models:
Attention to AC power quality and input inductance
enables a high power factor, consistent across all 3Φ
input voltages.
• Standard 37-pin isolated I/O and RS232
• Multiple front panel types for fl exibility
• Extensive programming interface options
• CE Mark safety and EMI/EMC certifi cation
• Made in USA
All products are designed and manufactured at
Magna-Power Electronics vertically integrated
headquarters in Flemington, NJ USA
Protective Diagnostic Features:
•
Over-voltage protection (OVT) (Programmable)
• Over-current protection (OCT) (Programmable)
• Over-temperature protection (THL)
• Interlock fault (LOC)
• Fuse fault (FUSE)
• Phase loss alarm (PHL)
• Analog programming line voltage fault (PGM LN)
• Remote sense lead detection (REM SEN)
Higher Quality Power Processing