Technical data

51EN 10/2010 i-KI MTD / i-KIR MTD
SYSTEM CONFIGURATION
U I A
Menu
Parameter
0101
Mixed zone 1 Mixed zone 2 Mixed zone 3
High temperature
zone 1 (fan coils /
radiators)
High temperature
zone 2 (fan coils /
radiators)
High temperature
zone 3 (fan coils /
radiators)
DHW
recircu-
lation
N-EM1
expansion
module
Mn01
0
X 0
Mn01
1
X X 1
Mn01
2
X 1
Mn01
3
X X 1
Mn01
4
X X X2
Mn01
5
X X X 2
Mn01
6
X X X X 2
Mn01
7
X X X X 2
Mn01
8
X X X X X 2
Mn01
9
X X 2
Mn01
10
X X X 2
Mn01
11
X X X X 2
Mn01
12
X X X X X 3
Mn01
13
X X X X X X 3
Mn01
14
X X X X 3
The heat pump controller can select configurations for 15 different types of system by setting parameter 0101.
The following table describes the system configurations available.
Configuration 0 does NOT require additional expansion modules
Configurations from 1 to 3 require 1 additional N-EM1 expansion module
Configurations from 4 to 11 require 2 additional N-EM1 expansion modules
Configurations 12, 13 and 14 require 3 additional N-EM1 expansion modules
The water connection and wiring diagrams for configurations from 1 to 14 are shown on the instruction sheet enclosed with the
N-EM1 expansion module.
The parameters required for correct system operation can be set on the A5 room controller supplied with the heat pump.
The next few pages are divided into the following sections:
Section 1 WATER CIRCUIT DIAGRAM
Section 2 WIRING DIAGRAM
Section 3 PARAMETER CONFIGURATION