User guide
500151R07
DAVISCOMMS (S) PTE LTD
Daviscomms Confidential Page 29 of 39
Canned messages configuration
at$tl=1,"Ignition On"
at$tl=2,”Ignition Off”
at$tl=3,"Main Battery Disconnected"
at$tl=4,"Internal Battery Disconnected"
at$tl=5,"Immobilisor Switched On”
at$tl=6,"Immobilizer Switched Off”
Events Defined
1) When ignition on, connect to TCP/IP and send canned message "Ignition on" and send GPS data
every 5 secs to TCP/IP server.
at$ed=1,1,"P08","P08"
at$ee=1,1,1,"$CO=1&1&1&1”
at$ed=2,1,”W9”,”W9”
at$ee=2,1,2,”$FT=1&1&0&10|$FT=2&1&0&60”
at$ed=3,1,”T01”,”T01”
at$ee=3,1,3,”$TC=1&'C7 S0'|$SRS='IgnOn'&'C7 S0'&5&0|$ED=4&1”
2) Configure MTD1000 to check and reconnect to server when GPRS socket is not present during IN-
1 is high.
at$ed=4,1,"T02 W9","T02 W1"
at$ee=4,1,4,"$SRS|$CO=0|$CO=1&1&1&1”
3) When ignition is off, send canned message ""Ignition off" to TCP server and disconnect server
connection.
at$ed=5,1,"P08","P00"
at$ee=5,1,5,"$SRS|$TC=2&'C7 S0'|$FT=5&1&0&5|$ED=4&0”
at$ed=6,1,”T10”,”T10”
at$ee=6,1,6,”$SRS='IgnOff’&'C7 S0'|$CO=0”
4) When external power is disabled, send message "External power disconnected" to SMS list and
send output to toggle relay device.
at$ed=7,1,”E01”,”E00”
at$ee=7,1,7,”$tc=3&’C0 S7’|$ps=1,0”
5) When internal battery is disabled, send message "Internal battery disconnected" to SMS list and
send output to toggle relay device.
at$ed=8,1,”B01”,”B00”
at$ee=8,1,8,”$tc=4&’C0 S7’|$ps=1,0”
6) Configure MTD1000 to reply SMS list "Immobilizer Switched On” when output 1 is low.
at$ed=9,1,”P01”,”P00”
at$ee=9,1,9,”$tc=5&’C0 S1’”
7) Configure MTD1000 to reply SMS list “Immobilizer Switched Off” when output 1 is high.
at$ed=10,1,”P01”,”P01”
at$ee=10,1,10,”$tc=6&’C0 S1’”
8) To disable or enable the output ports via SMS
$ps=1,0;
$ps=1,1
Note: Only index 1 of SMS list (at$cs) can control the MTD1000. Refer to page 18/73 MTD1000
commands guide R2.6.