Technical data
ELECTROFUSION POWER REQUIREMENTS
GENERATORS
For the installation of electrofusion fittings in field applications, it will be necessary to have a reliable source of
AC power for the Electrofusion Processor to work properly in supplying the fitting with the right amount of
energy. Generators used as an AC power source should conform to the following;
· Be well maintained and subjected to a periodic maintenance schedule;
· Provide an output voltage in the range that meets the specifications of the applicable
processor model;
· Operate within a frequency range of 45 Hertz minimum to 75 Hertz maximum;
· A minimum wattage capacity of;
Minimum Fitting Range
KVA
5.0 KVA Will fuse all Central Plastics fittings including 24" DIPS / 630 mm couplings
3.5 KVA Will fuse Couplings up to 8"/ 225 mm and all Tapping Tees, High Volume Tapping Tees,
Branch Saddles and Reducers
2.0 KVA Will fuse Couplings up to 1 1/4", and all Tapping Tees, High Volume Tapping Tees,
Branch Saddles and Reducers
·
A matching outlet is needed to mate with the plug equipped with the unit by Central:
120V models — 30 Amp, 125 Volt, NEMA L5, twist-lock;
INVERTERS
Inverters can be used as an acceptable AC power source but with the continuing changes in inverter technologies,
earlier processor models may not be compatible to the quasi-sine waveform produced by some inverters. Central
recommends performing compatibility tests using the lightest and heaviest anticipated loads before approving an inverter
system. Feel free to contact Central to discuss issues regarding the use of inverters.
EXTENSION CORDS
Due to the amperage draw of electrofusion fittings, use of extension cords are not encouraged but in the event it be-
comes necessary to use one the following lengths and wire gages are recommended:
Cord Length Wire Gage
25 ft. #10/3 wire (6 mm
2
)
50 ft. # 8/3 wire (10 mm
2
)
NO EXTENTION CORDS SHOULD BE USED ON 14” IPS & LARGER COUPLINGS
PIGTAILS - (30 Amp Twist Lock to 15 Amp Standard Plug Adapter)
The use of pigtails for in field applications of electrofusion fittings is not recommended except on fitting sizes 2" and
smaller.
POWERING UP
Prior to beginning the electrofusion sequence, it is important that you ensure the following:
· The generator has enough fuel to complete the electrofusion cycle
· The throttle is opened all the way (in anticipation of power draw)
IMPORTANT NOTE FOR COLD WEATHER INSTALLATIONS:
Cold weather affects both fittings and equipment. Electrofusion fittings require more energy at the beginning of the fusion
cycle, this requirement is increased in cold weather situations. Make sure that your generator is in good mechanical
condition and that it meets the minimum wattage output.
Page 2