Technical data
8.) Place the fitting on the area to be fused
and restrain using an approved restraint
device .(See “Restraint” page 7)
Use rubber mallet (or metal hammer and
wood blocks) to move coupler onto pipe, if
necessary. Ensure that stab depth marks
are properly located and visible.
9.) Attach processor leads to the fitting and
proceed with fusion as described for stan-
dard joining. (If using a Bar-Code Proces-
sor see “Scanning Instructions” page 8)
10.) Disconnect and remove processor
leads when fusion cycle is complete. It is a
good practice to note the time required
before clamp removal and mark it on the
fitting if necessary.
11.) Allow fitting to cool in accordance with
recommended cooling time before pressure
testing or rough handling. (See “Electrofu-
sion Cooling” page 9)