Operating instructions

TM 5-6115-584-12
NAVFAC P-8-622-12
TO-35C2-3-456-1
TM-05682C-12
b. Service
(1) Panel Light. Panel lamp cover can be re-
moved for cleaning by turning them counterclockwise
when viewed from front.
(2)
Panel Lamps. Panel lamps are screw in base
types and are replaceable.
3-20. FUEL SYS
TEM (LESS
TANK).
a. Inspect (see Figure 1-2.1). On ASK equipped generators,
remove FUEL FILTERS access door.
(1) Fuel Filter Assemblies (see figure 3-13). In-
physical damage. Check for leaks especially around
fuel line
fittings
(12), drains (1), and where bowl joins
the head Check that fuel filter assemblies are se-
curely attached to mounting bracket (16) and that
bracket is securely attached to bracket support on
skid-bass.
(2) Fuel Strainer Assembly (see figure 3-13).
Inspect strainer assembly (11) for dents or other phys-
ical damage. Check for leaks especially around fuel
line fittings (12), drain (1), or where the bowl joins the
head. Check that strainer assemblv (11) is securely
spect iwo fuel filter assemblies (10) for dents or other attached to mounting bracket (16).
1. Drain cock (3)
5. Elbow
9. Lockwasher (12)
13. Nut (2)
2. Hose assembly 6. Check valve
10. Filter (2)
14. Lockwasher (2)
3. Hose assembly (2)
7. Connector
11. Strainer
15. Screw (2)
4. Hose assembly 8. Screw (12)
12. Elbow (6)
16. Bracket
TS
6115-584-12/3-13
Figure 3-13. Fuel Filters and Fuel Strainer Assembly
Change 7
3-19