Specifications
SECTION VI. PERIODIC MAINTENANCE
6-1.
OVERVIEW. This section describes preventive
maintenance for the Rosemount Model PP814T Power
Positioner. Preventive maintenance is necessary at
specific intervals to reduce wear and tear on the
power positioner.
6-2.
TIME INTERVAL
(APPROXIMATE)
6 months
6 months
6 months
2 years
2 years
2 years
2 years
2 years
6-3.
MAINTENANCE SCHEDULE. Use the
maintenance schedule, Table 6-1, as a guideline for
preventive maiātenance. The frequency of this
maintenance varies directly with plant conditions and
operational load on the power positioner. Extremely
dusty conditions or high temperatures will require
more frequent maintenance on the power positioner.
GENERAL CLEANING AND LUBRICATION.
Clean power positioner exterior of all grease buildup
with commercial dry cleaning solvent. To lubricate
power positioner, refer to Figure 6-1, Lubrication
Chart.
Table 6-1. Maintenance Schedule.
MAINTENANCE ACTION
Perform general cleaning and lubrication. Refer to paragraph 6-3.
Clean and inspect pilot valve. Refer to paragraph 6-4.
Clean and drain air filter. Refer to paragraph 6-5.
Clean and inspect diaphragm. Refer to paragraph 6-6.
Clean and inspect air lock diaphragm. Refer to paragraph 6-7.
Clean and inspect exhaust blocking valve. Refer to paragraph 6-8.
Lubricate, clean and inspect cylinder and piston assemblies. Refer to paragraph 6-9.
Lubricate, clean and inspect mechanical linkage. Refer to paragraph 6-10.