Specifications

16
5. OPERATION
After running test and checks have been completed, the hoist will be ready for normal operation.
6. MAINTENANCE AND INSPECTION
6.1 Maintenance
(1) Check the level of gear box lubricant after first 500 hours of operation, thereafter every 3 months and
lubricant accordingly.
NOTE: WE RECOMMEND USING A LUBRICANT OIL EQUIVALENT TO ISO VG460.
(2) Always keep the hoist unit dry and never misuse it in a manner likely to reduce its durability.
WARNING
Since dealing with heavy loads may involve unexpected danger, all of the
"SAFETY RULES" (Ref 3.) must be followed and the operator must be aware
of the following points while using the hoist.
(1) The operator must have a clear and unobstructed view of the entire working area before
operating the hoist.
(2) The operator must check that the entire working area is safe and secure before operating
the hoist.
(3) When using the hoist with a motorized trolley, the operator must take care to prevent
excessive load swinging by sympathetic use of the trolley controls.
DANGER
Do not perform maintenance on the hoist while it is carrying a load except monthly
checking for the brake or limit switch.
DANGER
Before performing maintenance do not forget to affix tags to the power source and
the push button switch reading: “DANGER”, “EQUIPMENT BEING
REPAIRED”.