Specifications
Chapter 5 Operations
- 74 -
5-1-2 Setting parameters
Following test run of the actuator you can set the parameters via the parameter mode.
All parameters are dependant upon the driven machine system. The abstracts of the parameters in the
parameter mode are described in the table below:
Name Description Parameters
0: Control mode Selecting [position mode] or [speed mode]
[Position mode]⇒pulse train signal
[Speed mode]⇒analog voltage signal
0: position mode
1: speed mode
1: Command
configuration
Selecting a command configuration from
[2-pulse type],[1-pulse type]and [2-phase pulse type]
0: 2-pulse type
1: 1-pulse type
2: 2 phase pulse type
2: Multiplication of
2-phase pulse
Command pulse train multiplication when command
configuration is [2-phase pulse type].
1:
Same count of command
2: Double of command
4: Four times of command
3: Electric gear -
denominator
Denominator of electronic gear function to make simple
relation between displacement of driven mechanism and
command pulses.
Integer from 1 to 50
4: Electric gear -
numerator
Numerator of the electronic gear function Integer from 1 to 50
5: Error count clear
by Servo-ON
Clearing error count or not clearing by [servo-ON] input
signal.
0: No function
1: Clears it
6: Allowable
position error
Allowance of position error count ⇒ Alarm 60
1 to 1000
7: Zero clamp Clamp position or not in [speed mode] 0: No function
1: Zero clamp
8: Rotary direction Specifying the relation between command polarity and
rotary direction
0: FWD for positive com.
1:REV for positive com.
9: Speed
conversion factor
Rotary speed to command of 10V in [speed mode] 1 to max. motor speed
A: Speed limit Upper limit of motor speed 1 to max. motor speed
b: Torque limit Upper limit of motor torque; 100% to max. torque 1 to 100
c: Alarm logic Output signal logic of the alarm 0: normal close
1: normal open
(19) To enter the [parameter mode] from the [monitor
mode], press both the [ADJ] key and the [SET] key at
the same time at least three seconds.
⇒Enters [parameter mode] when there is no indication
on 4th to 6th digit.
Note: While [servo-ON: S-ON (CN2-3 pin)]
signal is ON, changing to parameter
mode will turn OFF the signal and the
system will go into the servo-OFF state.
D O W N
U P A D J S E T
D O W N
U P S E T
Monitor mode
Press 3 second.
Parameter mode