Specifications

Chapter 4 Installing HA-655 driver
- 64 -
4-5-3 Connecting power cables
The terminal block for the power is located on the front panel of the HA-655 driver. There is no phase
order in connection to three-phase power lines.
Shown the figure to the right, strip the end of wires of the power supply
cable and the motor cable, and connect wires to each terminal firmly.
Install an isolation transformer and noise filters in the power lines to
avoid electric shock and to guard against malfunctions caused by
external noise.
The driver contains a surge-current-suppress-circuit of capacitor type. Although the circuit reduces line
voltage fluctuation, avoid daisy-chain wiring of the power lines, and connect units with a main switch.
4-5-4 Isolation transformer
The use of an isolation transformer is recommended to
prevent problems caused by improper grounding and
external noises.
Optional transformers are available as follows:
FHA-17C
FHA-25C
FHA-32C
FHA-40C
Actuator
Unit Voltage
200V 200V 200V 200V
HA-655-2 PT1-20004 -
HA-655-4 - PT1-20008
Refer to appendix 1 for the details of the transformers.
HA-655
Main switch
Other
device
Other
device
Power
Other
device
Other
device
Power
Good connection
Bad connection
Main switch
HA-655
PT1-200 04-200
Ins. transformer: PT1 series
2nd volt. 200: AC 200V
2nd cur.
04:
4A
08: 8A
Prim. volt
100:
AC100V
115: AC115V
200: AC200V
220: AC220V
7mm
R
S
T
Noise filter
3-phase power (200V)
r
s
NF
NF
HA-655--200
R
S
T
Noise filter
Single phase power (200V)
r
s
NF
NF
Isolation
transformer
Isolation
transformer
Model:MVSTBR2.5/5
-
ST
-
5.08
(Phoenix contact)