Specifications
Chapter 6 Setting up parameters
- 119 -
[Test mode]
Analog monitor manual output (speed mode)
● Function
It is possible to output voltage signals manually through
the monitor ports in the speed mode. Two analog ports are
provided for monitoring.
Speed monitor: SPD-MON (CN2-23pin)
Current monitor: CUR-MON (CN2-24pin)
● Details of display
1st and 2nd digit: [An: analog monitor manual output]
3rd to 6th digit: indicates current output voltage.
● Operations
(1) To transfer to in the [analog monitor manual output]
mode, press the [ADJ] key at least 0.1 second.
⇒1st digit [A] flashes now you can output voltage
signals.
(Pressing the [ADJ] key at least 0.1 second again
inhibits the [analog monitor manual output].
(2) To output voltage from [speed monitor: SPD-MON (CN2-23pin)], press the [UP] key.
⇒While pressing, the pin continues to output varying voltage signal.
(3) To output voltage from [current monitor: CUR-MON (CN2-24pin)], press the [DOWN] key.
⇒While pressing, the pin continues to output varying voltage signal.
(4) To terminate [analog monitor manual output] operation, press the [SET] key at least 0.1 second.
⇒ Flashing of 1st digit stops and [analog monitor manual output] operation is inhibited.
D O W N
U P A D J S E T
Analog monitor
manual output
Indicates current output voltage
Unit: 0.1V
Range: -10V to +10V
1st digit
6th digit