Specifications
Chapter 6 Setting up parameters
- 117 -
[Test mode]
Output port operation (pos. / spd. mode)
● Function
It is possible to operate turn (ON/OFF) output ports
manually.
● Details of display
1st to 3rd digit: indicates the code for the output port.
4th to 6th digit: indicates current state of the port.
● Operations
(1) To operate output ports, press the [ADJ] key at least
0.1 second.
⇒1st digit flashes. You can operate output ports.
(Pressing the [ADJ] key at least 0.1 second again
inhibits [output port operation].
(2) Press the [UP] key to specify an output port to be
operated.
⇒Every pressing the key shifts the code number in
the order of the figures to the right.
(3) Press the [DOWN] key to operate ON/OFF the
selected. port.
⇒Every pressing the key alters the port state (ON→
OFF→ON→).
(4) To terminate the output port operation, press the
[SET] key at least 0.1 second.
⇒ Flashing of 1st digit stops and [output port
operation] is inhibited.
D O W N
U P A D J S E T
ON
OFF
In-position
IN-POS: CN2-33
Attained speed
HI-SPD: CN2-33
Alarm
ALARM: CN2-34
Alarm-A
ALARM: CN2-38
Alarm-B
ALARM: CN2-39
Alarm-C
ALARM: CN2-40
Alarm-D
ALARM: CN2-41
D O W N
U P A D J S E T
1st digit
6th digit