Specifications

Notes:
1. When “3” is selected in Box 2, “1”
must be selected in Box 7.
2. Aviation Fuel option can also be used
for diesel  uids.
3. For iPD and iPDR units, when “5”
is selected in Box 6, “10” must be
selected in Box 8.
4. When “3” is selected in Box 2, “3”
cannot be selected in Box 4.
5. Contact Parker for additional
communication options (RS485,
GPRS, LAN, WiFi, Sat, etc.)
6. The required connecting cables are
available as a kit. The kit consists of
two 5 meter cables (Communications
cable and Relay/Power Supply
cable) to enable all output options.
See Accessory table on page 37 for
applicable part number.
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8
IPD 1 2 2 2 2 1 30
BOX 1: Basic Assembly
Symbol Description
IPD Standard Particle Detector
IPDR Particle Detector - Robust Construction
IPDZ Particle Detector - Hazardous (Zone 2)
BOX 5: Limit Relay
Symbol Description
1 No (iPDR only)
2 Yes
BOX 4: Display
Symbol Description
1 None (iPDR, iPDZ only)
2 LED (iPD only)
3 Digital (iPD only)
BOX 8: Cable Connector
5
Symbol Description
10 Deutsch DT Series (iPD, iPDR only)
30 M12, 8-pin plug connector (iPD, iPDZ only)
40 M12, 12-pin plug connector (iPDR only)
BOX 2: Fluid Type
1, 2
Symbol Description
1 Mineral Oil
2 Phosphate Ester (iPD, iPDR only)
3 Aviation Fuel (4 channel) (iPD, iPDZ only)
BOX 3: Calibration
Symbol Description
2 MTD
BOX 6: Communication
3, 4
Symbol Pressure Setting
2 RS232 / 4-20mA
3 RS232 / 0-5V (iPD, iPDR only)
5 RS232 / CAN-bus (J1939)
BOX 7: Moisture
Symbol Description
1 No
2 Yes
icountPD
Ordering Information
39
Standard Default Settings for all icountPDs
Comms echo OFF
Verbose errors OFF
STI Senors used OFF
Reporting standards ISO
Particle limits 19/18/15
Measurement period 60 seconds
Reporting interval 30 seconds
Power-on mode AUTO
Auto start delay 5 seconds
Date Format dd/mm/yy
Default if Options Fitted
Relay hysteresis ON
Relay operation for particle limits ON
Relay operation for moisture sensor limits ON
Digital display orientation 0 degrees
Digital display brightness level 3-mid
0-5V/0-3V output voltage range 0-5V
Moisture sensor limit 70%