Specifications
icountPD/icountPDR/icountPDZ
Diagnostic self check start-up time 5 seconds
Measurement period 5 to 180 seconds
Reporting interval through RS232 0 to 3600 seconds
Digital LED display update time Every second
Limit relay output Changes occur +/- 1 ISO code at set limit (Hysteresis ON)
or customer set (Hysteresis OFF)
4-20mA output signal Continuous
Principle of operation Laser diode optical detection of actual particulates
Reporting codes ISO 7 – 21, NAS 0 – 12, (AS 00 – 12 contact Parker)
Icount will also report less than ISO 7, subject to the statistical uncertainty
de ned in ISO4406:1999, which is shown in the RS232, reporting results
as appropriate e.g “>6”
Calibration By recognized on-line methods, con rmed by the relevant International
Standards Organization procedures
Calibration recommendation 12 months (24 months for icountPDZ)
Performance +/- 1 ISO Code (dependant on stability of ow)
Reproducibility / Repeatability Better than 1 ISO Code
Power requirement Regulated 9 to 40Vdc
Maximum current draw 150mA
Hydraulic connection icountPD: M16 x 2 hydraulic test points (5/8” BSF for aggressive version)
icountPD Z2: Size: 066, Connection: EO 24 cone end
Flow range through the device 40 to 140 ml/min (optimum ow = 60ml/min)
Online ow range via System 20 Inline Sensors Size 0 = 1.59 to 6.6 gpm - (optimum ow = 3.96 gpm)
Size 1 = 6.34 to 26.4 gpm - (optimum ow = 18.5 gpm)
Size 2 = 44.9 to 100 gpm - (optimum ow = 66 gpm)
Required differential pressure across Inline Sensors 5.8 psi (0.4 bar) minimum
Viscosity range 10 to 500 cSt, 1 to 500 cSt
Temperature (icountPD and icountPDR) Operating environment: -4°F to +140°F (-20°C to +60°C)
Storage: -40°F to +176°F (-40°C to +80°C)
Operating uid: +32°F to +185°F (0°C to +85°C)
Temperature (icountPDZ) Operating environment: -22°F to +140°F (-30°C to +60°C)
Storage: -40°F to +176°F (-40°C to +80°C)
Operating uid: +41°F to +176°F (+5°C to +80°C)
Working pressure 30 to 6,000 PSI (2 to 420 bar)
Moisture sensor calibration ±5% RH (over compensated temperature range of +10°C to +80°C)
Operating humidity range 5% RH to 100% RH
Moisture sensor stability ±0.2% RH typical at 50% RH in one year
Certi cation IP66 rated (icountPD), IP69K (icountPDZ)
EMC/RFI – EN61000-6-2:2001(icountPD, PDR), EN6100-6-2:2005 (icountPDZ)
EN61000-6-3:2001(icountPD, PDR), EN61000-6-3:2007 (icountPDZ)
Materials Stainless Steel case construction (icountPDZ)
Stainless Steel hydraulic block (icountPD and icountPDR)
Viton seals, (icountPDZ: uorocarbon seals)
Dimensions icountPD: 7.2” x 6.1” x 3.4” (182mm x 155mm x 86mm)
icountPDR: 4.52” x 7.01” x 4.53” (114.7mm x 178.8mm x 115mm)
icountPDZ: 10.2” x 4.49” x 4.33” (260mm x 114mm x 110mm)
Weight icountPD: 2.9 lbs. (1.3 kg), icountPDZ: 5.73 lbs. (2.6 kg)
Default Settings See table on page 39
33