Specifications
Analyzing the Test Results
Once the automatic oil
sample test has been
completed, what next?
Solid contaminants in uid
power systems vary in size,
shape, form and quantity. The
most harmful contaminants
are normally between 6
microns and 14 microns. The
ISO code is the preferred
method of reporting quantity
of contaminants.
The ISO code number
corresponds to contamination
levels relating to three sizes.
The rst scale number
represents the number of
particles that are equal to and
greater than 4m (c) per ml of
uid, the second number for
particles that are equal to and
greater than 6 m(c) per ml of
uid and the third number for
particles that are equal to and
greater than 14 m(c) per ml
of uid.
For example: An ISO code
20/18/14 indicates that there
are between 5,000 - 10,000
particles that are equal to and
greater than 4m(c), between
1,300 - 2,500 particles that
are equal to and greater than
6m(c), and between 80 - 160
particles that are equal to and
greater than 14m(c).
20