Technical data
SightLine Applications Command and Control
10 Zoom scale factor applied to EO camera (1 … 255). Maps to
(0.9 … 1.1) or to (0.004 to 0.996), depending on Absolute Zoom
Mode in byte 4
11 Blend Mode
Value Description
0 don't change/default.
1 FrameBlend
2 ThermalBlend
3 NightBlend
4 Color Blend
12 Amount defines the amount of luminance information from the
EO (visible) camera to include in the blended result. Applies to:
FrameBlend, NightBlend, ColorBlend and ThermalBlend modes.
13 Hue scale factor. Amount of yellow hue to apply from bright
areas in the EO camera. Applies to: FrameBlend and
NightBlend modes.
14 Reserved
15 Reserved
16 EO camera index (0 to 4, default 1). This camera is warped into
the space of the other camera through the calibrations settings
before blending. It is assumed that this is the EO or visible
camera input for Thermal and Night blend modes. NEW 2.20.7
17 IR camera index (0 to 4, default 0). This camera is not warped
before blending. It is assumed that this is the IR or infrared
camera input for Thermal and Night blend modes. NEW 2.20.7
Current Image Size (0x4E)
Get Parameters Function (0x28)
Applies to the 0
th
(primary) camera. See Camera Display Order in Set Video Mode (0x1F) for camera
selection. The Display Rectangle can change depending on Display Mode (1up, 2Up, Side-by-Side,
etc.) also selected by the Set Video Mode command.
Byte offset Description
2 Packet length = 18
3 Packet Type = 0x4E
4 – 5 Capture Width
6 – 7 Capture Height
Copyright © 2014-2015 SightLine Applications, Inc. Page 77 of 95 Jan 15, 2015