Technical data

SightLine Applications Command and Control
Current Stabilization Parameters (0x41)
Get Parameters Function (0x28) Set Stabilization Parameters (0x02)
Describes the current stabilization mode. See also Set Stabilization Parameters (0x02) and Set
Stabilization Bias (0x12) .
Byte offset Description
2 Packet length = 6
3 Packet type = 0x41
4 Mode (default 9)
Bit Description
0
0 – Stabilization OFF
1 – Stabilization ON
1
0 – Enable
1 - Disable all registration, stabilization, enhancement
and tracking
2
0 – Previous images background
1 - Black background
3
0 – Auto bias disabled
1 – Auto bias enabled
Bit 4– 6 Reserved
Bit 7 0 – Enable PIP image micro stabilization
1 – Disable PIP image micro stabilization
5 Screen re-centering rate 0..255 (default 50)
6 Limit – maximum stabilization offset in pixels. 0 = no limit.
(default 0)
7 Angle Limit – maximum stabilization rotation angle in degrees.
(default 0)
Current Overlay Mode (0x42)
Get Parameters Function (0x28) Set Overlay Mode (0x06)
Byte offset Description
2 Packet length = 5
3 Packet type = 0x42
Copyright © 2014-2015 SightLine Applications, Inc. Page 69 of 95 Jan 15, 2015