Technical data

SightLine Applications Command and Control
Byte offset Description
2 Packet length = 3 (or 5 for 3000)
3 Type = 0x28
4 ID (0x1A, 0x23, or 0x29)
5 – 6 3000 only: [Optional] Network Display ID (0x0002=Net0,
0x0040=Net1), if not present, then Net0 is assumed
(*2)
Get Configuration (3000 only)
This packet gets sent from SLA-3000 as a response to the Get Parameter / Get Configuration
command.
Byte offset Description
2 Packet length = 14
3 Type = 0x01
4 Max number of camera inputs (always 3)
5 – 7 Reserved
8 – 11 Camera present bit pattern, bit0=Cam0, bit1=Cam1,... (e.g.
0x00000005 indicates Cam0 and Cam2 are connected)
12 – 15 Display present bit pattern (e.g. 0x00000083 indicates Analog,
Net0 and Net1 are available).
See “Display Destination” in Set Ethernet Display Parameters
command for display type values.
Set Ethernet Display Parameters (0x29)
Sets destination IP address and port number. Indicates whether address is Unicast or Multicast.
Configures output format of Ethernet Video.
Byte offset Description
2 Packet length = 9 (or 11 for 3000)
3 Type = 0x29
4 Bits Description
0..3 Video Mode
0 RTP MJPEG (default)
1 H.264
2 RTP MJPEG Source
Copyright © 2014-2015 SightLine Applications, Inc. Page 45 of 95 Jan 15, 2015