Technical data
SightLine Applications Command and Control
10
Automatically reset video decoder when failed frame synchronization
loss is detected
Value Description
0 Never
1 When frame synchronization loss detected
Set Stabilization Bias (0x12)
Adjust the stabilization solution by adding a constant bias in pixel coordinate space to the current
coordinates each frame. This is used to feed forward user controlled camera motion so that
stabilization does not “fight” against camera pan and tilt. Set “auto bias” mode to automatically
prevent the system from stabilizing against constant motion. Some amount of motion lag will still be
experienced in “auto bias” mode.
NEW 2.18 Manual bias offsets can be used in “auto bias” mode. In “auto bias” mode, set column and
row bias to 0 for “auto bias” only. Changes to the column and row bias values will be added to the
“auto bias” solution.
Byte offset Description
2 Packet length = 5
3 Packet type = 0x12
4 -128..127: Per frame column adjustment (bias) in pixels
(signed 8-bit integer)
5 -128..127: Per frame row adjustment (bias) in pixels
(signed 8-bit integer)
6 1 = Enable auto bias (combined auto + manual bias)
0 = Disable auto bias (manual bias only)
Set Metadata Data Values (0x13)
Sets new KLV metadata data values. Latest values are output with h.264 digital video stream.
Metadata is generated in accordance with MISB standards 0102.10, 0601.7, 0603.2, 0604.3, and
0903.3. Selectable KLV elements may be chosen from a superset of the Motion Imagery Sensor
Minimum Metadata Set defined in ST 0902.3. For conversion of values see Table 1 on page 16 of:
http://www.gwg.nga.mil/misb/docs/standards/ST060107.pdf.
Byte offset Description
2 Packet length = 44
3 Packet type = 0x13
4 – 5 Valid data bit mask. Update corresponding data element when bit
value = 1. Unsigned 16 bit integer
6 – 13 UTC time (bit 0) unsigned 64-bit integer
Copyright © 2014-2015 SightLine Applications, Inc. Page 26 of 95 Jan 15, 2015