Technical data

March 2009
33-88
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
Freedom
Accessories
DC Magnet Coils
When Ordering Specify
Conversion Kit for Field Assembly
■ Catalog Number
Factory Installed DC Coil
■ For factory installed DC magnet
coil on AC contactors or non-
combination starters (open type
only), substitute the Code Suffix
from table below for the magnet coil
identifier in the device Catalog
Number.
EXAMPLE: For Size 0 AC contactor
with a 24V DC coil, change
AN16BN0AC to AN16BN0T1C.
Application
■ Connect for separate control
■ Not for use with cover control
switch operators
■ Use twin break, heavy-duty pilot
devices.
■ Designed for +10%, -20% rated volt-
age, continuous duty operation.
Non-reversing Kit Consists of:
■ 1 Encapsulated DC magnet coil
■ 1 NCI or NO/NCI side mounted
auxiliary contact
Note: These kits are supplied with a
NO/NCI side mounted auxiliary contact
in place of the NCI contact.
■ 2 Blue colored connection wires
■ 1 Instruction publication
Operation
See next page for operation details.
Table 33-140. Product Selection
These kits are supplied with a NO/NCI side mounted auxiliary contact in place of the NCI contact.
Kit does not include mechanical interlock or crossover wiring. Two NO/NCI top mounted auxiliary contacts are supplied for electrical interlocking.
Factory installed DC coils on NEMA contactors and starters include a NO/NC top mounted auxiliary contact on each contactor for electrical interlock-
ing. On IEC contactors and starters, a NC top mounted auxiliary contact is supplied on each contactor for electrical interlocking.
Available factory assembled only.
Contactor or
Starter Size
Conversion Data Complete Conversion Kit Factory
Installed
Volts Magnet Coil NCI
Interlock
NEMA IEC Coil
Number
Amps
P.U./Seal
Watts
P.U./Seal
Catalog
Number
Price
U.S. $
Ship Wt.
Lbs. (kg)
Code
Suffix
Adder
U.S. $
Non-reversing — Kit includes NCI Side Mounted Auxiliary contact
00 and 0
CN35 – A, B, D
D15 Relays
A – F 12
24
48
120
9-2988-11
9-2988-12
9-2988-13
9-2988-14
6.4/.28
3.2/.14
1.6/.07
.64/.028
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
C320KGD1
C320KGD1
C320KGD1
C320KGD1
C335KD3R1
C335KD3T1
C335KD3W1
C335KD3A1
1.0 (.5) R1
T1
W1
A1
00 and 0
CN35 – A, B, D
D15 Relays
A – F 12
24
48
120
9-2988-11
9-2988-12
9-2988-13
9-2988-14
6.4/.28
3.2/.14
1.6/.07
.64/.028
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
C320KGD2
C320KGD2
C320KGD2
C320KGD2
C335KD3R4
C335KD3T4
C335KD3W4
C335KD3A4
1.0 (.5) R4
T4
W4
A4
1 and 2
CN35 – G
G – K 12
24
48
120
9-2990-1
9-2990-2
9-2990-3
9-2990-4
15.4/.42
7.7/.21
3.9/.11
1.5/.041
185/4.98
185/4.96
185/5.04
185/4.87
C320KGD5
C320KGD5
C320KGD5
C320KGD5
C335KD4R4
C335KD4T4
C335KD4W4
C335KD4A4
1.0 (.5) R4
T4
W4
A4
3
CN35 – K
L – N 12
24
48
120
9-3002-1
9-3002-2
9-3002-3
9-3002-4
24/.40
12/.20
6.1/.097
2.5/.038
293/4.84
288/4.75
295/4.67
298/4.57
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C335KD5R1
C335KD5T1
C335KD5W1
C335KD5A1
2.0 (.9) R1
T1
W1
A1
4 and 5
CN35 – N, S
P – S 24
48
120
240
9-2026-4
9-2026-3
9-2026-2
9-2026-1
18/.22
9/.11
3.3/.05
1.7/.02
400/5.3
400/5.2
450/5.4
440/4.9
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C335KA3T1
C335KA3W1
C335KA3A1
C335KA3B1
2.5 (1.1) T1B
W1B
A1B
B1B
Reversing
00 and 0
CN35 – A, B, D
D15 Relays
A – F 12
24
48
120
(2) 9-2988-1
(2) 9-2988-2
(2) 9-2988-3
(2) 9-2988-4
6.4/.28
3.2/.14
1.6/.07
.64/.028
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
(2) C320KGD1
(2) C320KGD1
(2) C320KGD1
(2) C320KGD1
C335RD3R1
C335RD3T1
C335RD3W1
C335RD3A1
1.0 (.5) R1
T1
W1
A1
1 and 2
CN35 – G
G – K 12
24
48
120
(2) 9-2990-1
(2) 9-2990-2
(2) 9-2990-3
(2) 9-2990-4
15.4/.42
7.7/.21
3.9/.11
1.5/.041
185/4.98
185/4.96
185/5.04
185/4.87
(2) C320KGD3
(2) C320KGD3
(2) C320KGD3
(2) C320KGD3
— R1
T1
W1
A1
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C