Technical data

March 2009
33-78
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
Freedom
Starters — 3-Phase Non-reversing and Reversing, Full Voltage, C396 Electronic Overload
Product Selection
Table 33-105. Type AN14/AN54 NEMA — C396 Selectable Reset Electronic Overload Relay — Non-reversing and Reversing
Underscore (_) indicates coil suffix required, see Table 33-106.
Underscore (_) indicates OLR designation required, see Table 33-107.
Underscore (_) indicates FLA range, see Table 33-108.
Starter is shipped unassembled. Catalog Number includes overload relay and contactor. Not a direct dimensional replacement for Size 4 Starter with
C306 bi-metallic overload.
Maximum horsepower rating of starters for 380V 50 Hz applications:
The service-limit current ratings represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods
in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its
continuous current rating. The current rating of overload relays or trip current of other motor protective devices used shall not exceed the service-limit
current rating of the controller.
Common control. For separate 120V control, insert letter D in 7th position of listed Catalog Number. EXAMPLE: AN54VND_ _ _.
Table 33-106. AC Suffix Code
NEMA Sizes 00 and 0 only.
NEMA Sizes 00 and 0 only. Sizes 1 – 8 are
24/60 only.
Table 33-107. OLR Designation
Table 33-108. C396 FLA Range (FNVR & FVR
Only)
Uses panel-mount CT with
C396A2A005SELAX Overload.
NEMA
Size
Cont.
Amp
Rating
Service-
Limit
Current
Rating
(Amps)
Maximum UL Horsepower
3-Pole
Non-reversing

3-Pole
Reversing

Vertical
Reversing

1-Phase 3-Phase
115V 230V 208V 240V 480V 600V Catalog
Number
Price
U.S. $
Catalog
Number
Catalog
Number
Price
U.S. $
00 9 11 1/3 1 1-1/2 1-1/2 2 2 AN14AN0_ _ _ AN54AN0_ _ _
01821123355AN14BN0_ _ _ AN54BN0_ _ _ AN54BNV_ _ _
1273223 7-1/2 7-1/2 10 10 AN14DN0_ _ _ AN54DN0_ _ _ AN54DNV_ _ _
2455237-1/2 10 15 25 25 AN14GN0_ _ _ AN54GN0_ _ _ AN54GNV_ _ _
390104 25 30 50 50 AN14KN0_ _ _ AN54KN0_ _ _ AN54KNV_ _ _
4
135 156 40 50 100 100 AN14NN0_ _ _ AN54NN0_ _ _ AN54NNV_ _ _
5 270 311 75 100 200 200 AN14SN0_ _ _ AN54SN0_ _ _
6 540 621 150 200 400 400 AN14TN0_ _ _ AN54TN0_ _ _
7 810 932 200 300 600 600 AN14UN0_ _ _ AN54UN0_ _ _
8
1215 1400 400 450 900 900 AN14VN0_ _ _ AN54VN0_ _ _
NEMA Size 00 0 12345678
Horsepower 1-1/2 5 10 25 50 75 150 300 600 900
Catalog Number AN14GN0_ _ _
Coil Volts and Hertz Code Suffix
120/60 or 110/50
240/60 or 220/50
480/60 or 440/50
600/60 or 550/50
A
B
C
D
208/60
277/60
208 – 240/60
240/50
E
H
J
K
380 – 415/50
550/50
24/60, 24/50
24/50
L
N
T
U
32/50
48/60
48/50
V
W
Y
OLR
3E = Standard C396 OLR, SEL Reset, SEL Class
NEMA Size FLA Range
00 P05 = 0.1 – 0.5A
002 = 0.4 – 2.0A
005 = 1.0 – 5.0A
008 = 1.6 – 8.0A
0 P05 = 0.1 – 0.5A
002 = 0.4 – 2.0A
005 = 1.0 – 5.0A
008 = 1.6 – 8.0A
032 = 6.4 – 32A
1 P05 = 0.1 – 0.5A
002 = 0.4 – 2.0A
005 = 1.0 – 5.0A
008 = 1.6 – 8.0A
032 = 6.4 – 32A
2 008 = 1.6 – 8.0A 045 = 9.0 – 45A
3 110 = 22 – 110A
4 150 = 30 – 150A
5
300 = 60 – 300A
6
600 = 120 – 600A
7
10C = 200 – 1000A
8
15C = 300 – 1500A
Technical Data –
Contactors . . . . . . . . . . . . . Pages 33-7933-81
Technical Data –
Overload. . . . . . . . . . . . . . . Page 33-113
Overload Relay. . . . . . . . . . Page 33-108
Dimensions . . . . . . . . . . . . Pages 33-9633-98
Special Modifications. . . . Page 33-90
Accessories . . . . . . . . . . . . Pages 33-8233-90
Discount Symbol . . . . . . . . 1CD1