Technical data

March 2009
33-74
For more information visit: www.eaton.com CA08102001E
NEMA Contactors & Starters
33
Freedom
Starters — 3-Phase Non-reversing and Reversing, Full Voltage
Technical Data
Table 33-96. Wire (75°C) Sizes — AWG or kcmil — NEMA Sizes 00 – 2 — Open and Enclosed
Two compartment box lug.
Minimum per NEC. Maximum wire size: Sizes 00 and 0 to 8 AWG and Sizes 1 – 2 to 2 AWG.
Table 33-97. Wire (75°C) Sizes — AWG or kcmil — NEMA Sizes 3 – 8 — Open and Enclosed
Minimum per NEC. Maximum wire size: Sizes 00 and 0 to 8 AWG and Sizes 1 – 2 to 2 AWG.
Wiring Diagrams
Figure 33-24. Typical Wiring Diagrams — Three-Phase and Single-Phase Applications
NEMA Size Wire Size
Cu Only
Power Terminals — Line
00
0
1
2
12 – 16 AWG stranded, 12 – 14 AWG solid
8 – 16 AWG stranded, 10 – 14 AWG solid
8 – 14 AWG stranded or solid
3 – 14 AWG (upper) and/or 6 – 14 AWG (lower) stranded or solid
Power Terminals — Load — Cu Only (stranded or solid)
00 – 0
1 – 2
14 – 6 AWG stranded or solid
14 – 2 AWG stranded or solid
Control Terminals — Cu Only
12 – 16 AWG stranded, 12 – 14 AWG solid
NEMA Size Wire Size
Power Terminals — Line and Load
3 1/0 – 14 AWG Cu/Al
4 Open — 3/0 – 8 AWG Cu; Enclosed — 250 kcmil — 6 AWG Cu/Al
5
6
7
8
750 kcmil — 2 AWG; or (2) 250 kcmil — 3/0 AWG Cu/Al
(2) 750 kcmil — 3/0 AWG Cu/Al
(3) 750 kcmil — 3/0 AWG Cu/Al
(4) 750 kcmil — 1/0 AWG Cu/Al
Control Terminals — Cu Only
12 – 16 AWG stranded, 12 – 14 AWG solid
Not for Use with
Auto Reset OL Relays
Separate Control
Remove Wire “c”
when it is supplied.
Connect separate
control lines to the
No. 1 Terminal on
the remote pilot
device and Terminal
96 on the overload
relay.
“c”
“A”
When more than
one pushbutton
station is used,
omit Connector
“A” and connect
per sketch.
Field Conversion
to 1-Phase, Add
Dotted Connections
Remote Pilot Devices
NEMA Size 00
2 Wire
Control
L1 L2 L3
T1 T2 T3
T1 T2 T3
1
A1 A2
A2
2
3
98
97
96
95
13
3
3
2
1
2
L1
T1 T2
T1 T2
L2
1
Start
Start Start
Stop
Stop Stop
3 Wire
Control
Motor
Motor
Not for Use with
Auto Reset OL Relays
Separate Control
Remove Wire “c”
when it is supplied.
Connect separate
control lines to the
No. 1 Terminal on
the remote pilot
device and Terminal
96 on the overload
relay.
“A”
When more than
one pushbutton
station is used,
omit Connector
“A” and connect
per sketch.
Field Conversion
to 1-Phase, Add
Dotted Connections
Remote Pilot Devices
NEMA Sizes 0, 1 and 2
2 Wire
Control
T1 T2
T3
“c”
L1 L2
L3
T1 T2 T3
1
A1
A2
2
3
98
97
96
95
13
3
3
2
1
2
L1
T1 T2
T1 T2
L2
1
Start
Start Start
Stop
Stop Stop
3 Wire
Control
Motor
Motor
Table 33-98. Plugging and Jogging Service
Horsepower Ratings
Maximum horsepower where operation is
interrupted more than 5 times per minute, or
more than 10 times in a 10 minute period.
NEMA Standard ICS2-1993 table 2-4-3.
Kits and Accessories
■ Auxiliary Contacts, contactor
mounted — Pages 33-86 – 33-87.
■ Transient Suppressor, for magnet
coil — Pages 33-84.
■ Timers — Solid-State and
Pneumatic, mount on contactor —
Page 33-83.
Renewal Parts Publication
Numbers
■ See Page 33-91.
NEMA
Size
200V 230V 460V 575V
00
0
1
2
3
—
1-1/2
3
7-1/2
15
1/2
1-1/2
3
10
20
1/2
2
5
15
30
1/2
2
5
15
30
4
5
6
25
60
125
30
75
150
60
150
300
60
150
300